I tested a 200 kWp system where the client suspected module degradation. The Z300 showed string resistance values between 0.8 and 1.1 ohm across most strings, but two strings came in at 4.2 and 6.7 ohm. That was enough to locate two faulty MC4 connectors that would never have been found with a standard IV curve tracer. The repair cost was minimal. The energy loss had been going on for over a year.

Richard Nyberg
Owner, Nybergs ElKonsult AB, Sweden

Finding faults that other instruments miss

Richard Nyberg runs Nybergs ElKonsult AB as a solo consultancy, specialising in solar PV design, installation and inspection across Sweden. As an independent consultant, every site visit has to deliver clear, defensible results he can stand behind when presenting findings to clients and installers.

He had worked with standard IV curve tracers and insulation testers before investing in the Z300. The turning point came on a 200 kWp commercial rooftop where the owner reported lower-than-expected yields but no obvious faults. A standard inspection had found nothing actionable.

The connector fault that cost a year of yield

Using the Z300 to measure series resistance (Rs) on every string, Richard found that the majority of strings measured between 0.8 and 1.1 ohm. Two strings returned values of 4.2 and 6.7 ohm respectively. Values that high pointed directly to a contact resistance fault rather than module degradation.

Physical inspection of the two outlier strings confirmed two degraded MC4 connectors. The connectors were replaced in under an hour. Yield monitoring in the weeks following the repair showed the affected strings back within normal range. The fault had been present and undetected for over a year.

200 kWp
System size inspected
6.7 ohm
Peak Rs fault value detected
1 yr
Fault undetected before Z300 inspection

Why Rs measurement changes the inspection workflow

For Richard, the value of the Z300 is not just in finding faults, it is in being able to show clients exactly where the fault is and why. A single number from a standard insulation tester tells you something is wrong. An Rs value of 6.7 ohm on one string while everything else reads below 1.1 tells you where to look and what to look for.

As a solo consultant, being able to test an entire rooftop array and identify outliers without an assistant or complex setup has changed how he prices and structures his inspection services. The cloud platform means all measurements are logged and exportable before he leaves the roof.

Instrument used
Z300 PVT
1500V professional PV tester with Rs, Riso, Voc and Isc measurement. Bluetooth connected to the emazys app and cloud platform.
View Z300 PVT →
Nybergs ElKonsult AB
Independent solar PV consulting, Sweden
Contact Richard Nyberg
Location Sweden
Sector Independent PV consultant
Team size Solo consultant
Instrument Z300 PVT
Use case O&M inspection, fault finding, client reporting
Request a quote